Enmet RECON-4 Bedienungsanleitung Seite 1

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Messgeräte Enmet RECON-4 herunter. ENMET RECON-4 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 17
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
ENMET Corporation
PO Box 979
Ann Arbor, MI 48106-0979
www.enmet.com
Manual Part Number
80006-034
January, 2011
RECON-4
Portable Multi-gas Detector Software Manual
Version
VersionVersion
Version:
:HW091211001
HW091211001HW091211001
HW091211001
Seitenansicht 0
1 2 3 4 5 6 ... 16 17

Inhaltsverzeichnis

Seite 1 - RECON-4

ENMET Corporation PO Box 979 Ann Arbor, MI 48106-0979 www.enmet.com Manual Part Number 80006-034 January, 2011 RECO

Seite 2

8 3.6 Data Print: Click the icon for “Data Print” to print out the data logs and event logs. 3.7 Delete History Data: 3.7.1 Click the icon for

Seite 3 - 1. Software Installation

9 3.8 Modify Parameters: Click the icon for “Modify Parameters” to open the window for modification of parameters. There are two parts of the “Modi

Seite 4

10 3.8.1.3 Modify Profiles: Check the “Profiles” box, select the alarm type that you prefer in the drop down menu, and then click Setup. 3.8.1.4 Mo

Seite 5

11 3.8.2 Modify Parameter of each sensor channel: The user can modify the calibration gas concentration, low alarm level and high alarm level of each

Seite 6

12 3.8.2.3 Channel 3— Carbon monoxide (CO) The Adjusting Concentration of the channel of CO can only be between 200.0 and 800.0 ppm. The Low alarm

Seite 7

13 NOTE FOR SECTIONS 3.9: The following sections 3.9, 3.9.1 and 3.9.2 describe advanced features of the RECON/4 which are currently under developmen

Seite 8

14 d. Select and open the calibration data file provided by the manufacturer. e. The calibration data will then be input into the RECON-4. f. Once

Seite 9

15 c. Select the location that you want to save the calibration data file. e. Then the calibration data will be transferred successfully.

Seite 11

1 Brief Introduction The RECON-4 Portable Multi-gas Detector Software is required for data management and reconfiguring of the RECON-4 portable mult

Seite 12

2 1.5 The shortcut is installed for the current user by default, and if you want to install a shortcut for all users, please select the second option

Seite 13

3 3. Using Portable Multi-gas Detector Software The software is used to: a. Set the user options b. Download data logs and event logs c. Data check

Seite 14

4 After downloading all the data logs and event logs to the computer successfully, it will show an indication window as follows: If there is no dat

Seite 15

5 3.3.2 Review data history by Date: Check the “Date” box, and then below it select the date range that you want to review. Then click, Review to dis

Seite 16

6 3.3.4 Review data history by Record Type: Check the “Record Type” box, and then below it in the drop down menu select the record type that you want

Seite 17 - 5. Exit the Software:

7 3.5 Output to Excel: Click the icon for “Output to Excel” to output the data to an Excel file. If there is no data to output to excel fi