
EX-6100
ENMET Corporation
10
6 Sensor Replacement
W
ARNING
:
Power must be removed from the EX-6100 before this or any internal procedure. Failure to do so may cause
damage to equipment, bodily injury or death.
6.1 Combustible sensor
Turn cover securing stud counter-clockwise to allow cover to open.
Remove cover by rotating counter-clockwise
Remove the display board - which can be left to dangle on its retaining wire. Remove the PCBs from the
support pillars and the ribbon cable from the board remaining in the enclosure.
Kommentare zu diesen Handbüchern